Semiconductors – 5M10.00

Remote Breathing Status Monitor – 5M10.10

  • The apparatus shows the temperature dependence of the electrical conductivity and exponential temperature dependence of the resistance of a sample of semiconductor material
  • It is used to produce an oscilloscope display that looks like a plot of a person’s inhaled and exhaled air temperature versus time.
  • A thermistor is placed at the location of the warm exhaled air.
  • The thermistor resistance will decrease and the current through and the voltage across the resistor in the apparatus will increase.
  • When the cooler air is inhaled, the thermistor resistance will increase and the current through and the voltage across the resistor will decrease.
  • The voltage across the resistor of the apparatus is displayed versus time on the oscilloscope screen.
  • The waveform looks like a plot of inhaled and exhaled air temperature versus time.
  • The small size and mass of the thermistor make possible rapid change in temperature and resistance.

Locations: Jacobs B122 – Shelf 264