{"id":12818,"date":"2001-01-01T00:00:00","date_gmt":"2001-01-01T08:00:00","guid":{"rendered":"https:\/\/www.hmc.edu\/clinic\/2001\/design-of-an-initiation-safety-device-for-the-sadarm-smart-munition\/"},"modified":"2001-01-01T00:00:00","modified_gmt":"2001-01-01T08:00:00","slug":"design-of-an-initiation-safety-device-for-the-sadarm-smart-munition","status":"publish","type":"post","link":"https:\/\/www.hmc.edu\/clinic\/2001\/design-of-an-initiation-safety-device-for-the-sadarm-smart-munition\/","title":{"rendered":"Design of an Initiation\/Safety Device for the SADARM Smart Munition"},"content":{"rendered":"<h2 class=\"project-sponsor-dept-year\"><span class=\"project-sponsor\">Aerojet<\/span> <span class=\"project-dept-year\">Engineering, 2000-01<\/span><\/h2>\n<div class=\"project-team\">\n<p><strong>Liaison(s):<\/strong> Daniel Pillasch,  Duncan Ewart<br \/>\n<strong>Advisor(s):<\/strong> Clive Dym<br \/>\n<strong>Students(s):<\/strong> Michelle McGraw (TL),  Michael Ferrante,  Tadashi Nagao,  Mika Waller<\/p>\n<\/div>\n<div class=\"project-abstract\">\n<p>The Clinic team is designing a new initation system for the SADARM Smart Munitions that will work in both spinning and non-spinning carrier shells. The current system uses centripetal force from the spin to ignite an impact-based pyrotechnical primer. The initiator must actuate two timing delay fuses upon ejection of the submunitions stacks from the carrier shell after launch. The system must also contain a safety mechanism to allow for safe download.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Aerojet Engineering, 2000-01 Liaison(s): Daniel Pillasch, Duncan Ewart Advisor(s): Clive Dym Students(s): Michelle McGraw (TL), Michael Ferrante, Tadashi Nagao, Mika [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[164],"tags":[550],"class_list":["post-12818","post","type-post","status-publish","format-standard","hentry","category-engineering","tag-aerojet"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hmc.edu\/clinic\/wp-json\/wp\/v2\/posts\/12818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hmc.edu\/clinic\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hmc.edu\/clinic\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hmc.edu\/clinic\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hmc.edu\/clinic\/wp-json\/wp\/v2\/comments?post=12818"}],"version-history":[{"count":0,"href":"https:\/\/www.hmc.edu\/clinic\/wp-json\/wp\/v2\/posts\/12818\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hmc.edu\/clinic\/wp-json\/wp\/v2\/media?parent=12818"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hmc.edu\/clinic\/wp-json\/wp\/v2\/categories?post=12818"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hmc.edu\/clinic\/wp-json\/wp\/v2\/tags?post=12818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}